SK-800KME
ME Jr. plus 2 Alarm Module
with Key Switch & Keypad
SK-800ME
ME Jr. plus 2 Alarm Module
with Key Switch Only
SK-800MEI
ME Jr. plus 2 Alarm Module
with Key Switch & Infrared Remote
Dip Switches
Fig. 6
4.
Fig. 7
Dip Switches Battery
SK-882 - Infrared
Remote Transmitter
Setting Up The Infrared
Remote:
1. Open the battery compartment door to reveal the dip switches on
the side of the SK-800MEI Alarm Module, as shown in Fig. 6.
2. Unscrew and open the SK-882 Infrared Remote. It is fastened
together with a small phillips head screw, shown in Fig. 7.
3. Arrange the Dip Switches into any configuration to create your
own encoded signal. Make sure the Dip Switches match on the
Alarm Module and the Infrared Remote Transmitter.
Note: It is highly recommended that you change the Dip Switch
settings from the factory default. This protects the system from being
tampered by anyone with an infrared remote set on the factory
default.
4. Close the Alarm Module and the Infrared Remote Transmitter.